SZ-V4: i-Link 4 Zone Valve Control FOR HYDRONIC RADIANT FLOOR HEATING SYSTEMS

SZ-V4: i-Link 4 Zone Valve Control FOR HYDRONIC RADIANT FLOOR HEATING SYSTEMS

The i-Link series Zone Valve Controls for hydronic radiant floor heating systems simplify the field wiring and yet control up to four zone valves in a multi-zone hydronic heating system. The contractor friendly Printed Circuit Board eliminates the problem caused by incorrect wiring and saves hours of installation time. There would be no more “messy” look of conventional zone valve installations. Intelligent Linking System (i-Link) allows unlimited zone expansion with additional i-Link controllers. Field selectable priority with Priority Protection Timer ensures other zones get heat every one hour and prevents freeze-ups in the event of a priority zone failure. The End Switch delay timer let the two wire type zone valves fully opened before turning on the circulator. The panel provides EZ screwless terminal blocks for connections to the thermostats and zone valves. In addition, LED indicators on the front panel provide functional status and easy troubleshooting.
  • US$150.00
 
OR

The i-Link series Zone Valve Controls simplify the field wiring and yet control up to four zone valves in a multi-zone hydronic heating system. The contractor friendly Printed Circuit Board eliminates the problem caused by incorrect wiring and saves hours of installation time. There would be no more “messy” look of conventional zone valve installations.

Intelligent Linking System (i-Link) allows unlimited zone expansion with additional i-Link controllers. Field selectable priority with Priority Protection Timer ensures other zones get heat every one hour and prevents freeze-ups in the event of a priority zone failure. The End Switch delay timer let the two wire type zone valves fully opened before turning on the circulator. The panel provides EZ screwless terminal blocks for connections to the thermostats and zone valves. In addition, LED indicators on the front panel provide functional status and easy troubleshooting.

Features:

* Front panel indicator lights

* Field selectable Priority

* Priority timer for protection of a priority zone malfunction and prevention of freeze-ups in the heating zones

* Unlimited zone expansion

* Three-minute End Switch delay timer for two wire type zone valve applications. Circulator will start only after the zone valve is fully opened.

* DIP switch for easy setup of two wire type zone valve applications. No need to hook up wire jumper on the third and fourth terminals on each zone

* Works with two, three or four wire type zone valves and thermostats

* Fuse protection

* Simplified wiring

* Contractor friendly PCB layout

* Easy-Connect Screwless Terminals

* 24VAC transformer output with common terminal provides compatibility with electronic thermostats

* Universal thermostat compatibility

* Isolated End Switch and Priority End Switch for utilizing full functionality of high efficiency Mod-Con boilers

* Pre-wired terminals for circulator

* SPDT Priority zone relay switch (N/O Com N/C). Capable of prioritizing DHW pump in a 2-pump system

* 50VA replaceable transformer

* 100% Factory Tested

* Extended three year warranty

Please click to view PDF Brochure

    • SKU
      SZ-V4

Customers who bought this product also bought

Customers who viewed this product also bought

Footer navigation